Why Powerflush?

Why we need to powerflush?

Every so often central heating systems and boilers can suffer from blockages, corrosion, leaks, loss of performance, noises, airlocks, poor efficiency and many more symptoms. The cause of these many problems can sometimes be due to the chemistry of the water running through the system. But what happens and why?

Corrosion Takes Hold

The materials we use in central heating are brass, copper, iron and steel, lead, aluminium, plastics and rubbers. The common factor we have amongst these materials is the water running through the system. What we can sometimes get if we aren’t careful is corrosion!

Catalytic Corrosion

When we install heating pipework we use a flux to clean the pipes and fittings, if we don’t remove this flux, it can turn the water in the system slightly acidic, then the materials in your system start reacting with each other in a undesirable way. As a by-product of this chemical reaction, we get black iron oxide and hydrogen. Thats black gooey water and lots of gas inside your system. Because the gooey water has slightly abrasive qualities, it acts like liquid sandpaper, rubbing your radiators thin from the inside, which can lead to pinholes and radiators splitting. And because you are getting lots of air in your radiators, things don’t work as well as they should do. It also gets into boiler and system components causing endless problems.

Symptoms = very black water in system, component failure, leaks, lots of air in radiators, noisy system,

Solution = powerflush and system protection filter, finished off with inhibitor

Oxidic Corrosion

There is another form of corrosion called oxidic corrosion. This is whereby air is getting into the system somehow, and causing your system to corrode from the inside. The main causes of this being lack of corrosion inhibitor in the system, or problems with pipework design around the pump.

When we fill our heating system up, we are put fresh oxygenated water into a system full of metal radiators. Taking radiators off to decorate and then refilling the system is a major cause of future problems, as the corrosion inhibitor is diluted, so it is important to get your inhibitor levels checked. For a system that by design heats up and cools down, rust will take hold within a short space of time. Inevitably we are going to get problems unless we do something to neutralise this reaction. So, we use something called Inhibitor, sometimes known by the brand name of “fernox”. This has special chemicals inside the stop the oxygen causing problems with the water and metal. But the design of the system can also cause a problem in introducing air into the system

 

How can pipework cause a problem?

If you have a tank fed system, you probably have a pump in the airing cupboard. Directly underneath the pump should be a feed (to bring cold water in) and vent (to push air out) pipe. If these two pipes are installed incorrectly you will get air problems. Because it’s on the inlet to the pump, its under negative pressure (sucking), so it may suck air instead of sucking water in. Once air is drawn into the system, if the pipework is incorrect, the system will not be able to naturally deal with it. Even if these pipes are correctly installed, blockages in these pipes can upset the balance, and it can mimic being incorrectly installed. One of the most common blockages in heating system is on the cold feed pipe directly underneath the pump. The point where it connects to the heating is normally a bottle neck for debris. We can normally test for blockages by using a magnet on the pipework, if the magnet sticks, the chances are it needs attention. Magnets don’t stick to copper, but they stick to the build up of iron oxide inside.

partly blocked pipe

The best way forward for pipework issues is to have them put right. There are so many installers who carry out a powerflush but leave or ignore the cause of the problem. Suffice to say future problems are imminent.

Symptoms = brown or orange water in radiators, noisy when first turned on, frequent bleeding of radiators required, failing components

Solution = powerflush, pipework alteration, system protection filter, inhibitor

symptoms requiring a powerflush

New installations

When installing a system from new, it is normally suffice to do hot and cold draindowns and refills without a powerflush machine. This should get the flux and installation debris out of a new install. However, when we install a new boiler on an old system, unless we are 100% sure that the system is clean, one should always seriously consider a powerflush. New boilers are particularly susceptible to debris and iron oxide left over from years of build up, and the waterways inside are a lot more delicate. It’s not worth the risk, boilers cost a lot of money, and it’s vital the water running through the system is clear. Manufacturers nowadays demand that systems are powerflushed, otherwise the warranty will be invalid until the water is proved to be clean.

What is a Powerflush?

So, we now know what the main reasons are as to why we need to get our system powerflushed. Exactly what is it?

Powerflushing is the removal of iron oxide sludge (dirty water in boiler and system) by means of a machine, connected to a central location. The two best places to connect the macine are where the central heating pump is fitted, or onto the feed pipes to the gas boiler. (Too many installers incorrectly connect the powerflushing machine onto a radiator fed by tiny pipe, for convenience because it’s in the hall, or by the back door. Straight away, this reduces the effectiveness of the powerflush, as the flow through the machine is governed by the pipework sizing of the radiator). Chemicals are added to the system to loosen the debris in the system. This is normally done in day, or ideally at least a week before the flush is done. Any remedial pipework alterations are now also carried out before we do the powerflush.

Typical Powerflush Machine (without the hoses)

Okay, so the machine is connected, now we isolate the feed tank in the loft and clean that by hand using soapy water. Onto the technical part, the powerflushing machine is going to push water around the radiators under high velocity, but low pressure (typically the same aount of pressure as your central heating pump), we need fresh cold water in, and we have a dump hose out, to get rid of the dirty water, so we need access to a foul drain. (If you have a no drains but a cesspit please check with your local authority regarding getting rid of the waste central heating water) So we are now blasting water round the system, just like a jet wash, and every now and again, we can reverse the flow on the machine backwards and forwards, to swish the dirt loose. It is also helpful if we can get the boiler to light whilst doing this, as the heat will give us a better resultant flush. If there are radiators with lots of cold spots, we may also use a soft rubber mallet to tap the bottom of the radiators, to help dislodge any stuck iron oxide that has clumped inside a radiator. If there are any problematic radiators, we can also isolate the other radiators and have the machine going around just those in question.

 

Finishing Off

After a while, the dirty water and chemicals will have been removed down the dump hose, and once it’s all clear, we can pack away, install any system protection filters, and remember to add inhibitor at the correct dose! The inhibitor needs to go directly into the system, and not just sitting in the feed tank in the loft where it will go all crusty!

The final part will be to balance the system. Water will naturally go down the easiest path, so some radiators might not get hot. To overcome this, the hotter radiators can be adjusted up or down. We normally turn one of the valves down, called the lockshield valve, it normally has a smooth cap on it that you can’t turn unless you remove the cap. The radiator will still get as hot, but with less water flowing through. Typically those upstairs get hotter first, as heat naturally rises, so we normally turn the ones upstairs down, and the one downstairs up!

 

Reap the Rewards

Once a powerflush has been done right, you can benefit from;

  • hotter radiators meaning slightly lower gas bills
  • not having to bleed radiators all the time
  • less callouts due to components failing
  • less noise from boiler and system having to work too hard

It is a long article, however I hope you now understand the importance of the poweflush for your central heating, and how the water in the system can cause so many problems if not correctly looked after.

As a footnote, if you have had a powerflush, or have decided to have one carried out, please make sure you get your inhibitor level checked every couple of years. For such a small cost, it can save a lot of problems further down the line!